NeuMeDx
Distributor of noninvasive impedance-based hemodynamic monitoring technologies focused on signal-morphology impedance cardiography for continuous cardiac output and related cardiovascular parameters. Offers PC-integrated monitoring systems, a portable exercise/ambulatory cardiac output monitor, a noninvasive central venous pressure method, consumable electrodes and clinical support materials. Emphasizes clinical validation, regulatory compliance and applications across physician offices, exercise physiology, emergency, perioperative and critical care settings.
Industries
Nr. of Employees
small (1-50)
NeuMeDx
Croydon, Pennsylvania, United States, North America
Products
Continuous noninvasive impedance cardiography monitor
A system that measures continuous noninvasive cardiac output, stroke volume and related hemodynamic parameters using signal-morphology impedance cardiography for clinical monitoring.
Portable exercise/ambulatory cardiac output monitor
A battery-powered portable monitor designed to obtain reliable cardiac output measurements during exercise and ambulatory protocols.
Noninvasive central venous pressure estimation device
A device that estimates central venous pressure using limb impedance measurements with cuff inflation and signal processing for front-line assessment.
Electrodes and electrode-preparation consumables
Consumable electrodes and recommended skin-preparation products aimed at reducing skin impedance and improving ECG/impedance signal acquisition quality.
Continuous noninvasive impedance cardiography monitor
A system that measures continuous noninvasive cardiac output, stroke volume and related hemodynamic parameters using signal-morphology impedance cardiography for clinical monitoring.
Portable exercise/ambulatory cardiac output monitor
A battery-powered portable monitor designed to obtain reliable cardiac output measurements during exercise and ambulatory protocols.
Noninvasive central venous pressure estimation device
A device that estimates central venous pressure using limb impedance measurements with cuff inflation and signal processing for front-line assessment.
Electrodes and electrode-preparation consumables
Consumable electrodes and recommended skin-preparation products aimed at reducing skin impedance and improving ECG/impedance signal acquisition quality.
Services
PC integration and real-time reporting
Software and system integration for real-time data capture, beat-by-beat monitoring, waveform display and cardiovascular report generation, with options for interfacing to bedside monitors.
Clinical validation support and study materials
Provision of validation study results, white papers, case studies and materials to support research, study design and clinical adoption.
Reimbursement and economic analysis support
Guidance on coding, reimbursement (including referenced billing codes) and financial modeling to assess cost-effectiveness and ROI for deployment in clinical settings.
PC integration and real-time reporting
Software and system integration for real-time data capture, beat-by-beat monitoring, waveform display and cardiovascular report generation, with options for interfacing to bedside monitors.
Clinical validation support and study materials
Provision of validation study results, white papers, case studies and materials to support research, study design and clinical adoption.
Reimbursement and economic analysis support
Guidance on coding, reimbursement (including referenced billing codes) and financial modeling to assess cost-effectiveness and ROI for deployment in clinical settings.
Expertise Areas
- Noninvasive hemodynamic monitoring and continuous cardiac output measurement
- Signal processing and motion-artifact tolerant impedance cardiography
- Exercise and ambulatory cardiac output assessment
- Perioperative, emergency and critical care hemodynamic optimization
Key Technologies
- Signal-morphology impedance cardiography
- Thoracic electrical bioimpedance
- Impedance plethysmography for pressure estimation
- Beat-by-beat hemodynamic analysis