Vasoptic Medical, Inc.
Vasoptic Medical, Inc. specializes in the development and deployment of advanced blood flow imagers and perfusion monitoring systems. They focus on noninvasive optical imaging technology to monitor and visualize tissue blood flow dynamics, providing solutions for clinical diagnostics and research. Their mission is to improve healthcare practice by making advanced blood flow data and insights accessible at the point of care, with a vision to advance blood flow monitoring tools for medical and academic communities.
Industries
Nr. of Employees
small (1-50)
Vasoptic Medical, Inc.
6751 Columbia Gateway Drive, Suite 300, Columbia, MD 21046 USA
Patents
Ophthalmic examination and disease management with multiple illumination modalities
US-11766172-B2
View DetailsSystem and method for rapid examination of vasculature and particulate flow using laser speckle contrast imaging
US-11666238-B2
View DetailsSystem and method for rapid examination of vasculature and particulate flow using laser speckle contrast imaging
US-11020015-B2
View DetailsOphthalmic examination and disease management with multiple illumination modalities
US-10722116-B2
View Details
Ophthalmic examination and disease management with multiple illumination modalities
US-11766172-B2
View DetailsSystem and method for rapid examination of vasculature and particulate flow using laser speckle contrast imaging
US-11666238-B2
View DetailsSystem and method for rapid examination of vasculature and particulate flow using laser speckle contrast imaging
US-11020015-B2
View DetailsOphthalmic examination and disease management with multiple illumination modalities
US-10722116-B2
View DetailsProducts
Clinical retinal blood flow imager (FDA-cleared Class II)
A clinical-grade noninvasive retinal blood flow imager that provides video-rate dynamic visualization and quantitative relative retinal blood flow estimates for use in ophthalmology and optometry.
Custom research ocular blood flow imager (investigational research use)
A research-oriented ocular blood flow imager based on the clinical design but modified for investigational use with configurable hardware and software tailored to study requirements.
Multimodal tissue speckle imager for laboratory use
A customizable laboratory imaging platform that uses laser speckle contrast imaging combined with fluorescence and reflectance imaging to assess perfusion and blood flow in optically accessible tissues in animal models.
Clinical retinal blood flow imager (FDA-cleared Class II)
A clinical-grade noninvasive retinal blood flow imager that provides video-rate dynamic visualization and quantitative relative retinal blood flow estimates for use in ophthalmology and optometry.
Custom research ocular blood flow imager (investigational research use)
A research-oriented ocular blood flow imager based on the clinical design but modified for investigational use with configurable hardware and software tailored to study requirements.
Multimodal tissue speckle imager for laboratory use
A customizable laboratory imaging platform that uses laser speckle contrast imaging combined with fluorescence and reflectance imaging to assess perfusion and blood flow in optically accessible tissues in animal models.
Services
Hardware and software modifications to ocular and tissue blood flow imagers to support research-specific needs (mounting configurations, extended acquisition, de-identified data workflows, and tailored analysis).
Operational support and user guidance to integrate blood flow imaging into clinical and laboratory workflows, including minimal-training workflows modeled on fundus photography.
Hardware and software modifications to ocular and tissue blood flow imagers to support research-specific needs (mounting configurations, extended acquisition, de-identified data workflows, and tailored analysis).
Operational support and user guidance to integrate blood flow imaging into clinical and laboratory workflows, including minimal-training workflows modeled on fundus photography.
Expertise Areas
- Ocular blood flow imaging
- Preclinical tissue perfusion imaging
- Laser speckle contrast imaging (LSCI) methods
- Multimodal imaging integration
Key Technologies
- Laser speckle contrast imaging (LSCI)
- High frame-rate video-rate imaging
- Fluorescence angiography integration
- High-contrast reflectance imaging
News & Updates
Vasoptic supported research assessing retinal blood flow changes using XyCAM CRE following bevacizumab treatment for retinopathy of prematurity (ROP).
Research article published in Ophthalmology Science by Wang J, Mansoor S, Wu J-Y, et al., 2025.
Research article in American Journal of Ophthalmology, 2025.
Study published in Scientific Reports, 2024.
Research article in Ophthalmology Science, 2023.
Research article in Ophthalmology Glaucoma, 2021.
Vasoptic supported research assessing retinal blood flow changes using XyCAM CRE following bevacizumab treatment for retinopathy of prematurity (ROP).
Research article published in Ophthalmology Science by Wang J, Mansoor S, Wu J-Y, et al., 2025.
Research article in American Journal of Ophthalmology, 2025.
Study published in Scientific Reports, 2024.
Research article in Ophthalmology Science, 2023.
Research article in Ophthalmology Glaucoma, 2021.