Stabiliz Orthopaedics
Stabiliz Orthopaedics is an orthopaedic device accelerator that designs, develops, and commercializes fracture fixation implants and systems. The company focuses on biomaterials-based implant solutions and rapid product development through surgeon partnerships, clinical validation (case reports and publications), and regulatory clearance to bring minimally invasive and time-adaptive fixation technologies to market.
Industries
Nr. of Employees
small (1-50)
Stabiliz Orthopaedics
Philadelphia, Pennsylvania, United States, North America
Patents
Products
SimpliFix Hip System
A fixation system for intracapsular femoral neck fractures using a headless cross-screw technique and instrumentation that enables surgeon-controlled compression to resist femoral neck shortening and minimize femoral head rotation.
SPL Locking Screws and Small Fragment Fixation System
A small-fragment plate and screw system that uses stainless steel screws with a resorbable PLGA locking mechanism that resorbs over ~4–6 months to reduce construct stiffness and promote interfragmentary motion.
QuikFix external fixation system (pending acquisition)
A single-use external fixation system designed to improve ease of use and efficiency, reduce reprocessing and re-sterilization risks, and lower hospital re-processing costs and space requirements.
SPL® Technology
Stabiliz Polymer Locking (SPL) Technology is a dynamic plate and screw system featuring stainless steel screws with a bio-resorbable PLGA locking mechanism that resorbs over time to reduce construct stiffness and promote fracture healing.
CORTICAL SCREWS
Non-sterile stainless steel cortical screws for bone fixation.
STRAIGHT LOCKING COMPRESSION PLATES
Stainless steel straight locking compression plates compatible with multiple screw types.
SimpliFix Hip System
A fixation system for intracapsular femoral neck fractures using a headless cross-screw technique and instrumentation that enables surgeon-controlled compression to resist femoral neck shortening and minimize femoral head rotation.
SPL Locking Screws and Small Fragment Fixation System
A small-fragment plate and screw system that uses stainless steel screws with a resorbable PLGA locking mechanism that resorbs over ~4–6 months to reduce construct stiffness and promote interfragmentary motion.
QuikFix external fixation system (pending acquisition)
A single-use external fixation system designed to improve ease of use and efficiency, reduce reprocessing and re-sterilization risks, and lower hospital re-processing costs and space requirements.
SPL® Technology
Stabiliz Polymer Locking (SPL) Technology is a dynamic plate and screw system featuring stainless steel screws with a bio-resorbable PLGA locking mechanism that resorbs over time to reduce construct stiffness and promote fracture healing.
CORTICAL SCREWS
Non-sterile stainless steel cortical screws for bone fixation.
STRAIGHT LOCKING COMPRESSION PLATES
Stainless steel straight locking compression plates compatible with multiple screw types.
Expertise Areas
- Orthopaedic device development
- Biomaterials for fracture fixation
- Fracture fixation system design (dynamic fixation)
- Preclinical biomechanical evaluation
Key Technologies
- Hybrid metal/resorbable polymer screw systems
- PLGA-based resorbable locking mechanisms
- Time-varying fixation constructs (delayed dynamization)
- Headless cross-screw fixation technique for femoral neck fractures
News & Updates
Release of new clinical case reports highlighting use of the SimpliFix Hip System.
Announcement of a definitive agreement to acquire an external fixation system developer with a single-use product.
Report of the first clinical cases using the SimpliFix Hip System performed by an orthopaedic trauma surgeon.
Announcement that the SimpliFix Hip System received U.S. FDA 510(k) clearance.
Company presence at Orthopaedic Trauma Association annual meeting to present and engage with clinical community.
Conference paper describing biomechanical evaluation of fixation constructs and relevance to femoral neck shortening and rotational control.
Release of new clinical case reports highlighting use of the SimpliFix Hip System.
Announcement of a definitive agreement to acquire an external fixation system developer with a single-use product.
Report of the first clinical cases using the SimpliFix Hip System performed by an orthopaedic trauma surgeon.
Announcement that the SimpliFix Hip System received U.S. FDA 510(k) clearance.
Company presence at Orthopaedic Trauma Association annual meeting to present and engage with clinical community.
Conference paper describing biomechanical evaluation of fixation constructs and relevance to femoral neck shortening and rotational control.