RadEye SPRD-GN
A pocket-size spectroscopic personal radiation detector by Thermo Fisher Scientific using RMD's Cs2LiYCl6:Ce (CLYC) scintillation crystals for gamma and neutron detection with high sensitivity and accuracy.
CLLBC-50-PHI-50-SiPM-187
Cylindrical CLLBC scintillator crystal, 50 mm diameter, 50 mm tall, permanently packaged with SiPM array(s) and temperature sensor, dual mode gamma-neutron detection at room temperature.
CLYC-50-PHI-50-S-114
6Li enriched cylindrical CLYC scintillation crystal, 50 mm diameter and 50 mm length, permanently mounted to a photomultiplier tube with less than 5% FWHM energy resolution at 662 keV line of 137Cs.
CLYC-50-PHI-50-P-118
6Li enriched cylindrical CLYC scintillation crystal, 50 mm diameter and 50 mm length, permanently mounted to a photomultiplier tube with less than 5% FWHM energy resolution at 662 keV line of 137Cs.
C7LYC-38-PHI-38-P-119
7Li enriched cylindrical CLYC scintillation crystal, 38 mm diameter and 38 mm length, permanently mounted to a photomultiplier tube with less than 5% FWHM energy resolution at 662 keV line of 137Cs, suppressing thermal neutron reactions for fast neutron spectroscopy.
Solid State
Photodetectors that convert light (photons) into current, used in medical imaging, radiation detection, x-ray detection, and infrared imaging.
Solid State Neutron Detector – Lithium Indium Selenide
Detecting thermal neutrons is a specialized area of instrument design because only certain materials can detect them effectively.
SRI-25-PHI-25-P-121
Cylindrical SrI2 scintillation crystal, 25 mm diameter, 25 mm length, permanently mounted to a photomultiplier tube. Energy resolution < 4 % FWHM at 662 keV line of 137Cs.
CLYC Gamma-Neutron Scintillation Detector
The CLYC scintillator Cs2LiYCl6:Ce is a dual-mode gamma-neutron scintillation detector used as a replacement for medium resolution gamma-ray detectors and Helium-3 proportional counter tubes for neutron detection. It offers pulse shape discrimination for neutron detection and better gamma-ray resolution than NaI or CsI, suitable for handheld instruments like personal radiation detectors, spectroscopic personal radiation detectors, and radioisotope identification devices.
CLYC-based neutron detector
A small and lightweight CLYC-based neutron detector that allows for a direct drop-in Helium-3 replacement of currently deployed tubes, featuring high thermal neutron detection efficiency, superior neutron and gamma detection and discrimination, and high-resolution gamma ray spectroscopy.
CLYC (Cs2LiYCl6:Ce) scintillation crystals
Scintillation crystals consisting of Cesium, Lithium, Yttrium, and Chlorine developed as a response to the Helium 3 shortage.
CLLBC (Cs2LiLa(Br,Cl)6:Ce) scintillator technology
A practical gamma-neutron detector used as a replacement for both high energy resolution detectors and neutron detectors.
Tl2LiYCl6 (TLYC) Thallium-based Elpasolite Crystal
Thallium-based elpasolite crystal combining features of NaI:Tl, LaBr3:Ce and He-3 for simultaneous gamma-neutron detection with pulse shape discrimination between gamma-rays and thermal neutrons.
Kromek M2R2 CLLBC Multimode Radioisotope Identification Detector (RIID) aka D5 RIID
A small, lightweight, easy to use wearable RIID with an expansive radioisotope library featuring a resolution of 3.5% and an ultra-low false alarm rate. It continuously scans and accurately identifies radiological threats in real time, even in mixed source environments.
Avalanche Photodiodes (APDs)
Silicon avalanche photodiodes (APDs) are solid-state detectors that provide signal gain by impact ionization, capable of directly detecting photons (low energy x-rays and UV/optical photons) and ionizing particles. They are thinner, more compact, and insensitive to magnetic fields compared to photomultiplier tubes (PMTs).
6LiI:Eu
6LiI:Eu is a scintillator film developed by Radiation Monitoring Devices for high spatial neutron imaging resolution, fabricated in large area microcolumnar format with optimized Europium dopant concentration to maximize neutron light yield.
LNI Scintillation Film
A microcolumnar scintillation film used in high-efficiency neutron detection and imaging with 45% concentration of 95% enriched 6Li, offering high brightness and excellent neutron-gamma discrimination.
GLuGAG Gamma-Neutron Ceramic Scintillation Detector
GLuGAG, (Gd,Lu)3(Ga,Al)5O12:Ce, is a gamma-ray ceramic scintillator from the garnet family with high light yield, density, good energy resolution, fast response, and good coincident timing resolution. It is suitable for high energy radiography, PET applications, and thermal neutron detection and imaging.
Tin-Loaded Organic Glass Scintillator
A novel organic scintillator developed by RMD with gamma-ray spectroscopy and neutron/gamma pulse shape discrimination comparable to liquid scintillators and single crystalline scintillators such as trans-stilbene. It allows gamma-ray spectroscopy, fast neutron detection, pulse shape discrimination between gamma rays and neutrons, and can be fabricated in large sizes. Boron loading enables thermal neutron detection in addition to fast neutron detection, PSD, and gamma-ray spectroscopy.
Neutron imaging components
Components used in neutron imaging detectors to produce visible images of neutron radiation.
Ceramic Scintillators
Ceramic scintillators are a type of Transparent Optical Ceramics (TOC), polycrystalline bodies composed of inorganic compounds.
32 CeBr3 Scintillation Crystal
Cerium Bromide (CeBr3) scintillation crystal developed by RMD for gamma ray detection, offering high light yield, fast response, high density, and very low intrinsic background noise compared to Lanthanum Bromide (LaBr3).
Lutetium Oxide (Lu2O3:Eu) Scintillator Film
Lutetium Oxide scintillator film with high density (9.5 g/cm3) and high effective atomic number (Zeff=63), light yield of 48,000 photons/MeV, peak emission at 610 nm, suitable for X-ray imaging from a few KeV to several MeV.
9-Phenylcarbazole (PCz) Organic Scintillation Crystal
Organic scintillation crystals are polycyclic aromatic hydrocarbon compounds that exist in single crystalline form.
9,10-Diphenylanthracene (DPA) Organic Scintillation Crystal
Organic scintillation crystals are polycyclic aromatic hydrocarbon compounds that exist in single crystalline form.
Strontium Iodide Scintillators (SrI2:Eu)
Strontium Iodide scintillators enable high resolution gamma-ray spectroscopy with high light output and exceptional linearity. They perform well at both high and low energies and reduce background counts and false alarms due to lack of intrinsic radioactivity. Used in hand-held Personal Radiation Detection instruments and other medical, industrial, and environmental applications.
Radcam radiation imaging camera
A radiation imaging camera system designed to produce visible images of radiation.
FPND: Amorphous Silicon Flat Panel based large area neutron detector
A high resolution neutron imager with a 25 x 30 cm active imaging area and intrinsic spatial resolution of 139 µm, designed for radiography using laboratory sources with time efficient imaging performance.
Anger Camera
SiPM based neutron imaging camera developed by Oak Ridge National Laboratory using a 500 µm thick LNI scintillator with 45% enriched 6Li, providing high spatial resolution down to 350 µm and efficient neutron-gamma discrimination.
Lens Coupled CCD Camera
High resolution, high frame rate, low noise neutron imaging detector using a commercial EMCCD coupled to a LNI scintillator, with adjustable image field of view and intrinsic resolution.
HSS-1 High-Speed Scintillator Film
High-speed custom scintillator film designed for fast framing applications, produced in desired large sizes and mass thickness.
Silicon Photomultiplier (SiPM)
A solid state alternative to photomultiplier tubes with single photon detection capability, fabricated using a standard CMOS process with integrated signal processing circuitry. Used with advanced scintillation materials for nuclear detection in science and security fields.
Wide Band Gap Solid State Photomultipliers (WBG-SSPM)
Prototype devices made from Aluminium Gallium Arsenide (AlGaAs) for wide band gap solid state photomultipliers, aimed at reducing noise characteristics compared to silicon photomultipliers.
Cesium Iodide Scintillator Film
Vapor-grown microcolumnar Cesium Iodide (CsI:Tl) scintillator film developed by RMD, standard for diagnostic digital radiography with high resolution X-ray imaging performance.
Cerium Bromoiodide (CBI) Thin-film Scintillator
A new, fast, bright, thin-film scintillator especially useful in applications that require high speed.
High-Speed Scintillation Screen (HSS)
A high-speed scintillation screen designed for high frame-rate X-ray imaging, offering fast and bright, afterglow-free emission, high X-ray absorption, and high spatial resolution for ultra-fast imaging.
MC-TF
A field-deployable device that first responders can use to quickly detect radiation.
Lu2O3:Yb3
Ceramic lutetium oxide doped with Yb3+ used as a scintillator material for PET imaging, high energy physics, and high energy radiography. It offers very fast decay time and high light yield, making it a promising replacement for lead tungstate (PbWO4).
LuI3:Ce - Cerium-doped Lutetium Iodide
LuI3:Ce is a high density, high effective Z microcolumnar scintillation screen for high speed X-ray imaging, offering high spatial resolution and extremely high brightness.
Structured CsI:Tl Scintillators
Structured CsI:Tl scintillators deposited on various substrates ranging in size up to 50 x 50cm and in thickness from tens of microns to over a millimeter, tailored for high spatial resolution, high detection efficiency, and enhanced brightness in digital X-ray imaging.
Thallium-doped, low-background sodium iodide scintillator crystals
High purity, low-background sodium iodide scintillators grown using the Bridgman-Stockbarger method, produced for dark matter and high energy physics studies requiring ultra-low radioactivity materials.
Thallium Bromide – TlBr
The semiconductor-material Thallium Bromide (TlBr) has been the focus of considerable research due to its properties.
Lithium Indium Selenide (LiInSe2)
A semiconductor material studied by RMD for nuclear and X-ray detection applications, focusing on room-temperature operable detectors with high efficiency and low electronic noise.
High Performance Custom-Designed X-ray Camera
An advanced high frame rate, large-area, modular X-ray detector capable of acquiring high-speed, high-resolution, high contrast images of dynamic phenomena, suitable for hypervelocity projectile tracking, impact analysis, high-speed medical X-ray CT, and time-resolved X-ray analysis.
HSSTM Scintillation Screens
18" x 18" scintillation screens offering fast and bright, afterglow-free emission, high X-ray absorption and high spatial resolution for ultra-fast imaging.
LPA-1
A portable X Ray fluorescence system for lead paint analysis, one of the most successful lead testing instruments ever developed.
Anisotropic Magnetoresistive (AMR) Sensors
Small, flexible, and lightweight sensors used to detect electrical currents moving through conductive surfaces for Non-destructive Testing (NDT).