Laguna Tech


Medical device company developing transcatheter aortic valve systems and delivery platforms. Activities described on the site include valve and delivery system design, tissue processing, in‑house manufacturing in Class 5/7 cleanrooms, and conduct of first‑in‑human and feasibility clinical studies for investigational transcatheter heart valves.

Industries

N/A

Nr. of Employees

small (1-50)


Patents

Prosthetic heart valve device, delivery system, interventional system and related method

US-12226313-B2

View Details

Prosthetic heart valve device

US-11806233-B2

View Details

Products

Balloon-expandable transcatheter aortic valve system

A balloon-expandable transcatheter aortic valve implant designed with multiple expanding support arms, low valve height, and a low-profile covered delivery system intended to treat aortic regurgitation and stenosis in a feasibility clinical setting.

Self-expanding transcatheter aortic valve system

A one-piece self-expanding transcatheter valve engineered with a low profile, multiple support arms for positioning, and a small-diameter delivery system intended for investigational treatment of aortic regurgitation.


Services

Manufacture and assembly of valve implants and delivery systems in certified Class 5 and Class 7 cleanrooms with processes oriented for clinical scale-up.

Expertise Areas

  • Transcatheter heart valve design
  • Delivery system engineering for TAVR
  • Cleanroom-based device manufacturing and scale-up
  • Tissue processing for valve implants
  • Show More (4)

Key Technologies

  • Balloon-expandable transcatheter valve design
  • Self-expanding transcatheter valve design
  • Low-profile delivery catheter architecture (16F access)
  • Deflectable and steerable delivery catheters
  • Show More (4)

News & Updates

Announcement that first-in-human clinical case was completed and additional patients treated with an investigational self-expanding valve system; reported complete resolution of aortic regurgitation maintained at 30-day follow-up for two patients.

Report that the first patient was treated in a first-in-human feasibility trial of an investigational self-expanding transcatheter aortic valve to treat aortic regurgitation; 30-day follow-up outcome reported for the first patient.

Announcement that five patients were treated at a single center on the same day in an ongoing feasibility trial for an investigational balloon-expandable transcatheter valve; reported immediate procedural resolution and 24–48 hour discharge for those cases.

Site-reported set of clinical cases (including six reported cases with 30–60 day follow-up) in feasibility/first-in-human studies showing resolution of aortic regurgitation immediately post-procedure.

Announcement of a granted U.S. patent (US 11,806,233) strengthening the company's intellectual property position in the transcatheter valve space.


Similar organizations

Browse all ORGANIZATIONS

JOIN OUR MAILING LIST

Stay Connected with MTEC

Keep up with active and upcoming solicitations, MTEC news and other valuable information.