Pump tubing, fittings, caps and containers
Supply of peristaltic pump tubing, fittings, connectors, sample caps and containerware for analytical workflows.
Chemicals, reagents and standards
Analytical-grade reagents, surfactants, indicators and calibration standards for flow-based methods.
EasyChem 200
The Systea EasyChem 200 is an analyzer capable of analyzing many different chemistries with minimal hands-on time and low operational consumable costs, optimizing lab workflow. It features automatic washing of the sampling probe, high throughput of at least 60 results per hour, and flexible software for worklist management and LIMS integration.
EasyChem 200 Reagent Kit for Alkalinity, 1000 Samples
Includes 100 ml of pH Buffer (R1) and 100 ml of Methyl Orange (R2)
EasyChem 200 Reagent Kit for NOX Vanadium, High Level, 1000 Samples
Includes 50 ml of Color Reagent (R1) and 10 20 ml Aliquots of Vanadium Reagent (R2)
EasyChem 200 Reagent Kit for PO4, High Level, 1000 Samples
Includes 3 50ml Aliquots of Color Reagent (R1) and 6 10ml Aliquots of Ascorbic Acid (R2)
EasyChem 200 Reagent Kit for NO2, Low Level 1000 samples, High Level 500 samples
Includes 50 ml of Color Reagent (R1) for nitrite (NO2) analysis at low and high levels.
EasyChem 200 Reagent Kit for NOX Vanadium, Soils, 50ppm Range, 500 Samples
Includes 100 ml of Color Reagent (R1) and 3 20 ml Aliquots of Vanadium Reagent (R2)
Amperometric Flow Cell Assembly
The complete Amperometric Flow Cell kit includes the Amperometric Flowcell, 0.005” Gasket (326791), Reference Electrode (329513), 3000 grit working electrode polishing sandpaper and an allen wrench. Can also be used on the Systea Flow Systems and older OI Analytical systems such as the FS3000, FS3100 and FSIV.
Amperometric Flow Cell Assembly – Lower
Amperometric Flow Cell Assembly – Lower
Amperometric Flowcell
A flowcell designed for amperometric cyanide analysis, compatible with FS3000 or FS3100 analyzers, available for upgrade to the newest version.
Amperometric Flowcell Screws, SS 1 1/4" Length (6 pack)
Set of 6 stainless steel screws for amperometric flowcell assembly, 1 1/4 inch length.
Amperometric Flowcell Ring Washer
Ring washer for amperometric flowcell assembly.
Amperometric Flowcell Counter Electrode Upgrade Kit
Upgrade kit for amperometric flowcell to enhance basic functionality.
0.030 ID, Black/Black,
EZkem’s 2-stop 6" collar x 36" length peristaltic pump tubing used for Ismatec peristaltic pumps in Alpkem, OI Analytical, Latchat and other brands of autoanalyzers for flow injection (FIA) and segmented flow (SFA) analysis.
0.030 ID, Black/Black, 3×36 2-Bridge Pump Tubing
EZkem’s 2-stop 3" collar x 36" length peristaltic pump tubing used for Ismatec peristaltic pumps in Alpkem, OI Analytical, Latchat and other brands of autoanalyzers for flow injection (FIA) and segmented flow (SFA) analysis.
Membrane, 25 mm,
EZkem’s 25 mm Polypropylene Gas Diffusion Membrane is used for Cyanide or Ammonia/ TKN analysis in the gas diffusion module. Pack of 10.
Tubing Kit
TKN/NH3 Gas Diffusion, FS3700, SFA Tubing Kit for gas diffusion applications in analyzers.
Tubing Kit – Available CN, OIA-1677, FS3700, FIA
Available CN Tubing Kit for OIA-1677, FS3700 & FIA.
FS3100/FSIV
Membranes designed for gas diffusion applications compatible with FS3100 and FSIV analyzers.
FS3100/FSIV Waste Line Tubing
Waste line tubing designed for FS3100 and FSIV gas diffusion systems.
Cadmium Coil, 10 turn, 24 inches, for Discrete Analyzers
Cadmium reduction coil with 10 turns and 24 inches length for discrete analyzers.
Cadmium Coil – 24 inch
EZkem open tubular cadmium reactor (OTCR) Cadmium coil – 24 in. length, compatible with Alpkem, OI Analytical, Technicon, or Latchat auto analyzers or discrete analyzers such as FSIII & FSIV, flow injection analyzers (FIA), and segmented flow analyzers (SFA).
24 inch OTCR Cadmium Coil
A 24-inch open tubular cadmium reaction coil designed for use on newer, more powerful flow analyzer instruments to maintain reduction efficiency.
12 inch OTCR Cadmium Coil
A 12-inch open tubular cadmium reaction coil designed for use on RFA instruments with slower pump speeds and reduced solution volumes.
Cadmium Coil, 6 inches (pair)
Pair of cadmium coils, each 6 inches length.
Flow Solution® 3100
A Segmented Flow Analysis (SFA) system used for the determination of ammonia in estuarine and coastal waters (seawater) according to USEPA Method 349.0 and Standard Methods 4500–NH3 G. It analyzes ammonia by forming indophenol blue and measuring absorbance at 640 nm.
Flow Solution 3700
A flow analysis system used for various chemical determinations including ammonia, chloride, fluoride, phenol, nitrate, and nitrite in water samples.
Flow Solution 3000
A flow analysis system used for various chemical determinations including ammonia, chloride, fluoride, phenol, nitrate, and nitrite in water samples.
Flow Solution IV
A flow analysis system used for various chemical determinations including ammonia, chloride, fluoride, phenol, nitrate, and nitrite in water samples.
OI Analytical Flow Solution FS 3100 Automated Ion Analyzer
An automated ion analyzer system designed for high throughput, low interference nutrient analysis of soil and plant samples using continuous flow analysis.
Micromac-1000
Portable Analyzer for Water Online Monitoring that performs high sensitivity multiparametric analysis using wet chemistry methods in the field. It supports a wide range of EPA approved applications including nutrients analysis in seawater.
Micromac Smart
Portable analyzer easy to install and operate, delivered fully factory tested and ready to use. Reagent kits available for all standard measurements.
Micromac C
A rugged, highly automated analyzer designed for industrial water monitoring, capable of processing various analytes efficiently with minimal maintenance and consumables.
Micromac Compact
Microprocessor controlled Portable analyzer specifically designed for automatic analysis on several types of water matrices. Can be used as Laboratory, On Line or Portable analyzer for field measurements in environmental emergencies.
Reference Electrode
Reference electrode for amperometric cyanide analysis, designed for use with FS3000 or FS3100 analyzers.
Reference Electrode Cell, Flat Bottom, Old Style Amperometric Flowcell
Reference electrode cell with flat bottom design for old style amperometric flowcells.
Gas Diffusion Module,
PVDF gas diffusion module with mix T's, wide channel, Type C design for enhanced gas diffusion.
Gas Diffusion Module, Acrylic with Stand-offs, also Type C
Acrylic gas diffusion module with stand-offs, compatible with Type C membranes.
Cable, FS3100 Amperometric Detector to Old Style Flowcell
Cable connecting FS3100 amperometric detector to old style flowcell.
Cable, FS3100 Amperometric Detector to FS3700 Upper & Counter Electrode
Cable connecting FS3100 amperometric detector to FS3700 upper and counter electrode.
Systea EasyChem Plus
A fully automated discrete analyzer ideal for running chemistries on sea water, wastewater, soils, plants, feeds, and fertilizers. It performs up to 60 tests an hour with features like a cooled reagent tray, temperature controlled reaction tray, and colorimetric detector with automatic wavelength selection.
Vials, 12 ml, 16 x 100 mm, Polystyrene, 1000 count
12 ml (16 x 100 mm) sample vials for Cetac 60 Place rack and Systea FlowSys autosampler. Case of 1000. Used in Alpkem, OI Analytical FSIII/FSIV and Systea FlowSys autoanalyzers, flow injection analysis, segmented flow analysis.
Ismatec Peristaltic Pump Tubes
Peristaltic pump tubes with color-coded collars indicating inner diameter (ID) for flow rate control, used in various autoanalyzers like OI Analytical, Lachat, Skalar, Seal, Astoria Pacific, and Alpkem systems.
Sample Cups, 4 ml, polystyrene
4 ml sample cups, polystyrene, case of 1000 for various autosamplers used in Alpkem and OI Analytical FSIII & FSIV auto analyzers, flow injection analysis, and segmented flow analysis.
Vials, 8 ml, 13 x 100 mm, Glass, 1000 count
Glass vials with a volume of 8 ml and dimensions of 13 x 100 mm, sold in a pack of 1000.
E100057 Upper Amperometric Flowcell Assembly
Upgrade a FS3100 flow cell with the upper portion of the Ampermetric Flow Cell for better sensitivity, compatible with original A002299 amperometric cable on the detector. Uses the new style Reference Electrode 329513.
FLOWSYS III
A continuous flow analyzer that offers high performance, low running costs, and a user-friendly interface for analyzing water, soil, plants, feeds, or fertilizers. Ideal for labs seeking in-line sample preparation including digestion, distillation, and gas diffusion.
Systea Easy 1 Vanadium Reagent - 48 pack/30ml each
The EZkem Systea Easy 1 Vanadium Reagent is used for Systea Discrete Analyzers as well as any other type of discrete analyzer. It is applicable to the analysis of nitrate in wastewater, drinking water, seawater, and soil extractions.
Vials, 30 ml, 25 x 95 mm, Polypropylene, 10 count
EZkem’s polypropylene vials are used primarily on Cetac Autosampler Standard Racks.
10 mm Flow Cell for FS3100/ FSIV
EZkem flow cell made of PEEK material, leak and flow tested, designed for Alpkem and OI Analytical detectors with sensitivities from 5 to 40 mm.
Connector, 4-way Splitter, 0.023 ID
EZkem’s 4-way, 0.023 ID splitters can be used with various tubing. They are often used to connect tubing from the autosampler to the peristaltic pump.
3×24 Viton Pump Tubing
Viton pump tubing compatible with Flowsys analyzers, sized 3×24.
Viton / Acid Flex
Specialty peristaltic pump tubing made from Viton or Acid Flex materials for chemical resistance.
Type C Membrane
The Type C Membrane (25 mm) is used on polysulfone gas diffusion modules for soil and dairy analysis, specifically for analysis of Phosphate, Nitrate, and Nitrite by dialysis.
Polysulfone Gas Diffusion Modules
Gas diffusion modules made of polysulfone with options for wide or narrow channels, deep or shallow depth, and with or without mix-T's.
Probe, 12″ PEEK with Tubing Assembly
A 12-inch probe made of PEEK material with tubing assembly for autosamplers.
2-Stop Pump Tubing - 6" Collar x 36" Length
Pump tubing with a 6 inch collar and 36 inch length, designed for use in laboratory analyzers.
Probe, PEEK 12" CETAC samplers
12 inch PEEK probe for CETAC autosamplers.
Sample Tray, 90 Position Tray for Autosampler
Sample tray with 90 positions for laboratory autosamplers.
Bitterness in Beer Cartridge
A cartridge used in the OI Analytical Bitterness Analyzer for automated determination of bitterness in filtered beer or wort.
Injection Loop Tubing Assembly, 250 uL
Tubing Assembly, Injection Loop, 250 uL for analytical instrumentation.
Manifold, 6 port, Acrylic, FS3100 Cartridge
6 port acrylic manifold for FS3100 cartridge analyzers.
2-Stop Pump Tubing - 3" Collar x 24" Length
Pump tubing with 2 stops, featuring a 3-inch collar and 24-inch length, designed for use in laboratory analyzers.
A002848 Gas Diffusion Module Acrylic with Mix Ts
A gas diffusion module made of acrylic, used in amperometric detection systems.
Debubbler Pull Off
Tubing Assembly, Debubbler Pull Off for use in laboratory analyzers.
Cartridge Rebuild
Builds, reconditions and repairs over 30 different types of cartridges including Total Phosphorous, Nitrate/Nitrite, Ammonia/Total Kjeldahl Nitrogen (TKN), Post Distill Phenol, Orthophosphate for Alpkem and OI Analytical autoanalyzers.
PEEK Adapter, Old Style Amperometric Flowcell
PEEK adapter for old style amperometric flowcell.
Ismatec Pump Repair Services
Three levels of repair service for Ismatec peristaltic pumps used in autoanalyzer flow analysis systems: Pump Reconditioning Service, Pump Rollerhead Rebuild, and Pump Repair Service.
7 Turn, 15 inch Cadmium Coil
EZkem’s 7-turn 15 inch Cadmium Coil can be used for any discrete analyzer such as Systea EasyChem Analyzers or Unity SmartChem Analyzers.
Gasket, Amperometric Flowcell for Cyanide Analysis, 0.005
Gasket for amperometric flowcell used in cyanide analysis, thickness 0.005 inches.
CNSolution 9310 Cyanide Analyzer
An on-line cyanide analyzer designed to measure and control cyanide used in hydrometallurgical leaching of gold and silver from ores. It can be used as a benchtop analyzer for grab samples or deployed for on-line measurements and process control.
TKN by Gas Diffusion Cartridge
A cartridge used in the Flow Injection Analysis (FIA) system for the determination of Total Kjeldahl Nitrogen (TKN) in water and waste samples.
Flanged Fittings
Flanged fittings made from Teflon tubing that use an o-ring and a melted or compressed ring of the tubing end to create a seal without occluding the tubing opening, providing better flow and longer life compared to ferrules.
5 mm Flow Cell for FS3700
EZkem flow cells for the FS3700 platform detectors are used for a wide range of sensitivities from 5 to 20 mm to fit your application. Each flow cell has been leak and flow tested.
Wiz Probe
State of the art, EPA award-winning portable “in-situ” probe that can automatically analyze up to four chemical compounds in surface and sea water. Innovative design allows easy handling and field deployment by a single user.
Photodiode
EZkem’s photodiode assembly is used for ER digital detectors in the FSIII, FSIV & FS3000 Apkem and OI Analytical auto analyzers, flow injection analysis, and segmented flow analysis.
Manifold, 5 port, Polysulfone, FS3000 Cartridge
5 port polysulfone manifold for FS3000 cartridge.
Manifold, 10 port, Polysulfone, FSIII/FSIV Cartridge
10 port polysulfone manifold for FSIII/FSIV cartridge.
Distillation Coil, Heater Spool Assembly
EZkem’s distillation coil is a heater spool assembly which is used for Alpkem and OI Analytical auto analyzers, flow injection analysis and segmented flow.
Sandpaper, 3000 grit, Amperometric Flowcell Polishing
3000 grit sandpaper for polishing amperometric flowcells.
Cartridge to Debubbler (EVA)
Tubing Assembly, Cartridge to Debubbler with Ferrule (EVA) for laboratory use.
1000 nm Filter
EZkem filters are used for photometric ER detectors which are used in Alpkem and OI Analytical auto analyzer ER detectors, flow injection analyzers and segmented flow analyzers.
Cadmium Reduction Coil
A coil used for the reduction of nitrate to nitrite in autoanalyzers such as Flow 3000, Flow 3100, and Flow IV, designed to replace granulated cadmium packed columns for safer and faster nitrate analysis.
UV Lamp, 8W 312nm 12 inches used in CN analysis
UV lamp with 8W power and 312nm wavelength, 12 inches long, used in cyanide analysis.
Distillation Head with Tubing
Laboratory distillation head supplied with tubing for sample processing.
Valve Rebuild
Service to clean and replace all tubing, flow test for functionality of valves on the FS3000 platform to extend valve life.
Bottle-Reference Electrode Storage CNS
Storage bottle for reference electrodes used in cyanide analysis.
Debubbler, Acrylic
EZkem’s acrylic debubbler with 1/4-28 fittings is used primarily for ER detectors, but can also be adapted to any segmented stream.