CMS
Importer and regional distributor of medical devices since 1996, operating in Brazil and Chile. Focus areas include interventional cardiology, endovascular therapy, structural/congenital interventions, and a portfolio for endoscopy and endocirurgia. Associated manufacturing arm produces minimally invasive device lines; the group also conducts clinical research and organizes education and training for clinicians.
Industries
Nr. of Employees
medium (51-250)
CMS
Rua 18, Lote 06, Polo Empresarial Goiás - Aparecida de Goiânia - GO, CEP: 74.985-249, Brazil
Products
Self-expanding covered endograft with electrospun membrane
Flexible self-expanding endograft comprised of a laser-cut nitinol frame encapsulated by a thin electrospun polymer membrane for endovascular repair.
Drug-eluting coronary stent with biodegradable polymer coating
Coronary sirolimus-eluting stent platform using a cobalt-chromium backbone with thin struts and an abluminal PLA/PLGA coating engineered for early drug release and full polymer degradation.
Balloon-in-balloon double-balloon delivery catheter
Non-compliant double-balloon catheter for staged stent expansion with radiopaque markers and defined introducer and guidewire compatibilities.
High-pressure semi-compliant balloon catheters
Single- and multi-lumen balloon catheters for valvoplasty and angioplasty with rapid deflation, Y-lumen designs and specified nominal/burst pressures and volumes.
Microcatheter systems for physiologic assessment
Rapid-exchange microcatheter systems designed to enable fractional flow reserve measurements while allowing physician choice of 0.014" guidewire.
Introducer sheaths and access kits (including multi-access introducers)
Long radiopaque introducer sheaths and multi-access introducer systems supplied with compatible dilators and hemostatic valves for percutaneous vascular access.
Self-expanding covered endograft with electrospun membrane
Flexible self-expanding endograft comprised of a laser-cut nitinol frame encapsulated by a thin electrospun polymer membrane for endovascular repair.
Drug-eluting coronary stent with biodegradable polymer coating
Coronary sirolimus-eluting stent platform using a cobalt-chromium backbone with thin struts and an abluminal PLA/PLGA coating engineered for early drug release and full polymer degradation.
Balloon-in-balloon double-balloon delivery catheter
Non-compliant double-balloon catheter for staged stent expansion with radiopaque markers and defined introducer and guidewire compatibilities.
High-pressure semi-compliant balloon catheters
Single- and multi-lumen balloon catheters for valvoplasty and angioplasty with rapid deflation, Y-lumen designs and specified nominal/burst pressures and volumes.
Microcatheter systems for physiologic assessment
Rapid-exchange microcatheter systems designed to enable fractional flow reserve measurements while allowing physician choice of 0.014" guidewire.
Introducer sheaths and access kits (including multi-access introducers)
Long radiopaque introducer sheaths and multi-access introducer systems supplied with compatible dilators and hemostatic valves for percutaneous vascular access.
Services
Commercial supply and regional distribution of interventional cardiology, endovascular, structural and endoscopy devices to hospitals and clinics.
Organization and support of webinars, live-case demonstrations and training courses related to physiologic assessment, imaging and interventional procedures.
Sponsorship and collaboration for clinical studies evaluating device performance, including imaging follow-up and public registration of trials.
Commercial supply and regional distribution of interventional cardiology, endovascular, structural and endoscopy devices to hospitals and clinics.
Organization and support of webinars, live-case demonstrations and training courses related to physiologic assessment, imaging and interventional procedures.
Sponsorship and collaboration for clinical studies evaluating device performance, including imaging follow-up and public registration of trials.
Expertise Areas
- Interventional cardiology devices
- Endovascular stent and endograft systems
- Minimally invasive device development and manufacturing
- Drug-eluting stent coating development
Key Technologies
- Nitinol laser-cut stent structures
- Electrospun polymer membrane fabrication
- Biodegradable polymer (PLA/PLGA) drug-eluting coatings
- Cobalt-chromium stent platforms
News & Updates
Webinar covering the value of rapid-exchange microcatheter-based FFR in different clinical scenarios.
Participation in an online live-case course on complex cardiac interventions including a live QFR case presentation.
Announcement describing a self-expanding covered endograft comprised of a laser-cut nitinol structure and electrospun membrane receiving CE marking.
Description of a third-generation sirolimus-eluting coronary stent platform with biodegradable PLA/PLGA coating and thin strut design.
Summary of a clinical study that evaluated strut coverage rate after stent implantation using serial optical coherence tomography at 1, 2 and 3 months.
Webinar covering the value of rapid-exchange microcatheter-based FFR in different clinical scenarios.
Participation in an online live-case course on complex cardiac interventions including a live QFR case presentation.
Announcement describing a self-expanding covered endograft comprised of a laser-cut nitinol structure and electrospun membrane receiving CE marking.
Description of a third-generation sirolimus-eluting coronary stent platform with biodegradable PLA/PLGA coating and thin strut design.
Summary of a clinical study that evaluated strut coverage rate after stent implantation using serial optical coherence tomography at 1, 2 and 3 months.